Avaya the Business Policy Switch 2000 Software Version 2.5.2 Notice Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 26
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Resolved issues 15
Release Notes for the Business Policy Switch 2000 Software Version 2.5.2
The following issues were resolved in version 2.0.5.20:
Downloading an ASCII configuration file will no longer result in a broadcast
storm on a BPS 2000 switch that is set to DMLT. (CR Q00514963)
Configuring an MLT link (two ports on the same unit) will no longer cause a
loop when the switch is reset. (CR Q00514981)
In previous releases, in a mixed or pure stack, with IGMP and static router
port configured, if multiple VLANs were created and then one VLAN in the
middle of the table was deleted at later time, DMLT/MLT trunks did not
function correctly. This has been corrected in software release 2.0.5.20.
IGMP queries are no longer sent to a port that is configured as static router
port, received queries are forwarded to ports only if the Unknown Multicast
feature is enabled.
The following issues were resolved in version 2.0.5:
When configuring Port Mirroring on a specified MAC address, resetting the
switch no longer causes instabilities in the system. (CR Q00155176)
When deleting a VLAN member of a Spanning Tree Group (STG), the first
port of the MLT is now correctly removed from the STG. (CR Q00316370)
You no longer need to reboot the BPS 2000 switch when you add a policy
where you configure shaping parameters. (CR Q00139108)
When using Web management on a stack of BPS 2000 switches and accessing
the Port Error Summary page, if the page contains more than six entries, the
system will no longer hang. (CR Q00170933)
The command
dot1dStpPortEnable.x now works properly to disable a
port. (CR Q00391212)
The Redundant Power Supply Unit (RPSU) LED no longer returns the wrong
value when using Device Manager. (CR Q00279588)
You can now log in via the Web interface using RADIUS authentication.
(CR Q00416483)
You can now use the CLI to configure flow control for BPS 2000-2GE ports.
(CR Q00415228)
When autonegotiation is enabled for a Gigabit link, the flow control menu in
the Web interface no longer offers the choice of Symmetric or Asymmetric.
Flow control is disabled. (CR Q00416485)