Avaya 4600 Series IP Telephones Application Note Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 10
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
RL; Reviewed:
WCH 10/22/2004
Solution & Interoperability Test Lab Application Notes
©2004 Avaya Inc. All Rights Reserved.
7 of 10
Alpine3808-PoE.doc
Enter the command show inline-power info ports <portlist> to obtain inline power information
for one or more ports. The output of the command displays the inline power state, detected
802.3af class, actual power consumption, and fault state on each specified port.
Alpine3808:275 # show inline-power info ports 5:1-5:16
Port State Class Connect Volts Curr Res Power Fault
History (mA) (Kohms) (Watts)
5:1 delivering class1 1 50.1 62 25.2 3.10 None
5:2 delivering class2 2 50.1 62 25.2 3.20 None
5:3 delivering class2 3 49.8 64 24.8 3.20 None
5:4 delivering class3 4 49.8 138 24.4 6.90 None
5:5 delivering class3 5 49.8 120 24.0 6.00 None
5:6 delivering class3 6 49.8 212 24.0 10.60 None
5:7 delivering class3 7 49.8 106 24.4 5.30 None
5:8 delivering class0 8 49.8 94 24.8 4.60 None
5:9 delivering class0 9 49.8 92 24.4 4.60 None
5:10 delivering class0 10 49.8 98 24.0 4.90 None
5:11 delivering class0 11 49.8 112 25.2 5.60 None
5:12 searching ------ 0 0.0 0 0.0 0.00 None
5:13 searching ------ 0 0.0 0 0.0 0.00 None
5:14 searching ------ 0 0.0 0 0.0 0.00 None
5:15 searching ------ 0 0.0 0 0.0 0.00 None
5:16 searching ------ 0 0.0 0 0.0 0.00 None
For more detailed inline power information for one or more ports, enter the command show
inline-power info detail ports <portlist>.
4. Interoperability Compliance Testing
The interoperability compliance testing focused on verifying PoE interoperability between the
Extreme Networks Alpine 3808 and Avaya 4600 Series IP Telephones and Avaya AP-4/5/6
Wireless Access Points.
4.1. General Test Approach
The general test approach was to connect the Avaya PDs (Avaya 4600 Series IP Telephones and
Avaya AP-4/5/6 Wireless Access Points) to PoE-enabled ports on the Alpine FM-32Pi PoE
Module and verify that the PDs successfully boot. To test repeatability, PoE was then disabled
and enabled again on the connected ports. Lastly, to verify that power and data can be
simultaneously carried on the PoE connections, phone calls were made from the IP Telephones
and an IP Softphone on a wireless laptop accessing the network via the AP-4/5/6.
4.2. Test Results
All test cases completed successfully. The Alpine 3808 equipped with an Alpine FM-32Pi PoE
Module successfully provided inline power to the Avaya PDs. Table 1 below lists the 802.3af
class, allocated power, and measured power of the Avaya PDs when connected to the Alpine
FM-32Pi PoE Module. All of the IP Telephones were in idle/on-hook states.