Avaya 6424D+M User Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
S-Registers
The S-registers provide a means of changing or reading selected ADM options. In most cases,
the values defined for the S-registers listed in Table 3-3 are acceptable. However, if the values
are not acceptable, use the information below to change the values.
To view the value of a particular S-register, type
ats
n?, and
RETURN
(where the value of "n" is
the register you want).
RETURN
.
The value of the S-register "n" can be changed by typing
ats
n=value
RETURN
.
Table 3-3: S-Registers
S-Register Table
Register Description Default Comments
Controls the
Answer option
000
001
0 = manual
1 = auto
S0
S1 - - not used
ASCII value of the
Attention
sequence
decimal value of
ASCII character
used for Attention
sequence
S2 043 (+++)
Defines carriage
return
013 (carriage
return)
decimal value of
ASCII character;
used to end
command line and
to end result code
S3
Defines line feed
character
decimal value of
ASCII character;
used after carriage
return only when
verbal result codes
are enabled (see
atvn command in
Table 3-2)
S4 010 (line feed)
Defines backspace
character
decimal value of
ASCII character
used as backspace
S5 008 (backspace)
S11 & S88 see API manual
return zeros when
read; value set is
ignored
All others
Using the CMD and AT Commands 3-11
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 73 74