Page 1 - Hardware & Installation

BCM450 Rls 6.0 Hardware & Installation Task Based Guide

Page 2 - All Rights Reserved

BCM450 Hardware & Installation 10 NN40011-001 Issue 1.2 BCM450 Rls 6.0 IP telephony features BCM450 offers the complete range of IP telephony f

Page 3

BCM450 Hardware & Installation 100 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Avaya Documentation Links  Installation – System  Upgrade Guide

Page 4 - Table of Contents

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 11 Redundancy Options The BCM450 supports the following Redundancy opti

Page 5

BCM450 Hardware & Installation 12 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Flow Chart The flow chart below describes the BCM450 installation proces

Page 6

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 13 Wall Mount Brackets If the BCM450 and any expansion units are to be

Page 7

BCM450 Hardware & Installation 14 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Desk Mounting the BCM450  Attach the supplied rubber feet  Position

Page 8

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 15 Connect the ports on station modules only to approved digital teleph

Page 9 - Available Features

BCM450 Hardware & Installation 16 NN40011-001 Issue 1.2 BCM450 Rls 6.0  mounting hardware (either a rackmount shelf, a wallmount bracket per

Page 10 - BCM450 Additional Components

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 17 5. Position the main unit in the rack. You may require assistance t

Page 11 - Chassis Interface Card

BCM450 Hardware & Installation 18 NN40011-001 Issue 1.2 BCM450 Rls 6.0 5. Install four #10 x 2.5 cm (#10 x 1 in.) round-head screws

Page 12

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 19 Media Bay Modules Media Bay Modules are installed in the BCM450‘s ma

Page 13 - Rack Mount Brackets

BCM450 Hardware & Installation 2 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Copyright © 2010 Avaya Inc. All Rights Reserved. Notices While reasonable

Page 14 - Planning the Installation

BCM450 Hardware & Installation 20 NN40011-001 Issue 1.2 BCM450 Rls 6.0 The DTM module supports the following protocols:  PRI  DASS2  DPNS

Page 15 - Environment Checklist

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 21 Caller ID Trunk Media Bay Module There are two types of Caller ID tr

Page 16

BCM450 Hardware & Installation 22 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Global Analog Trunk Media Bay Module The Global Analog Trunk Media Bay M

Page 17

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 23  Enhanced ringing capability — ASM8+ and GASM8 provide a ringing v

Page 18

BCM450 Hardware & Installation 24 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Global 4x16 and Global 8x16 Module This is a combination module that pr

Page 19 - Media Bay Modules

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 25  Analog Extension Module (Norstar Analog Station Module in Element

Page 20

BCM450 Hardware & Installation 26 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Note: The ASM8/8+ and GASM MBM‘s support 8 analog stations. ADID4/8 Med

Page 21

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 27 GATM4/8 Media Bay Module Amphenol Wiring Use the table below if conn

Page 22

BCM450 Hardware & Installation 28 NN40011-001 Issue 1.2 BCM450 Rls 6.0 G4/8x16 Media Bay Module Amphenol Wiring The G4/8x16 MBM‘s is a combinat

Page 23

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 29 There are 4 line ports for analog trunks, and an auxiliary port next

Page 24

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 3 Downloading documents For the most current versions of documentation,

Page 25 - Wire Colour

BCM450 Hardware & Installation 30 NN40011-001 Issue 1.2 BCM450 Rls 6.0 DTM Ports The digital trunks are connected to the DTM via the RJ-48C jac

Page 26

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 31 Installing Media Bay Modules The BCM450‘s main unit can accommoda

Page 27

BCM450 Hardware & Installation 32 NN40011-001 Issue 1.2 BCM450 Rls 6.0 configured within Element Manager. During the MBM‘s configuration

Page 28

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 33 4. Push the MBM completely into the MBM bay. You should hear a c

Page 29 - BRI Ports

BCM450 Hardware & Installation 34 NN40011-001 Issue 1.2 BCM450 Rls 6.0 1. To remove a media bay module from the main unit, pull the lever adj

Page 30 - DTM Ports

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 35 Installing a BCM450 Expansion Unit Adding a BCM450 Expansion Un

Page 31 - Installing Media Bay Modules

BCM450 Hardware & Installation 36 NN40011-001 Issue 1.2 BCM450 Rls 6.0 The BCM main unit and expansion unit are each powered through an AC o

Page 32

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 37 UPS and BCM450 The BCM450 system can also be powered via connection

Page 33

BCM450 Hardware & Installation 38 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Powering Up the BCM 1. Ensure your BCM450 power supply is connect

Page 34

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 39 The table below outlines the various System LED states a

Page 35

BCM450 Hardware & Installation 4 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Table of Contents Hardware & Installation ...

Page 36

BCM450 Hardware & Installation 40 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Power Status Description Start-up Profile LED states (seen only during

Page 37 - UPS and BCM450

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 41 Additional Information The following sections contain procedures tha

Page 38 - LED Status

BCM450 Hardware & Installation 42 NN40011-001 Issue 1.2 BCM450 Rls 6.0 5. Use a grounding strap and attach one end to your wrist and the other

Page 39

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 43 7. Pull the base function tray levers towards you, the base functio

Page 40

BCM450 Hardware & Installation 44 NN40011-001 Issue 1.2 BCM450 Rls 6.0 10. There is a plastic cover on the CEC slot of the BCM Main Unit. 1

Page 41 - Additional Information

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 45 13. Screw the four metal standoffs into the main board of the base f

Page 42

BCM450 Hardware & Installation 46 NN40011-001 Issue 1.2 BCM450 Rls 6.0 14. Move the CEC into position from the back of the base function tray.

Page 43

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 47 17. The Capacity Expansion Card is now secured to the Base Functio

Page 44

BCM450 Hardware & Installation 48 NN40011-001 Issue 1.2 BCM450 Rls 6.0 18. Reinstall the base function tray and power on the BCM450 system. P

Page 45

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 49 Removing the Base Function Tray (BFT) The base function tray can

Page 46

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 5 Powering Up the BCM ...

Page 47

BCM450 Hardware & Installation 50 NN40011-001 Issue 1.2 BCM450 Rls 6.0 8. Hold the levers and pull the tray until it is removed from the ma

Page 48

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 51 Installing a Base Function Tray A base function tray can be r

Page 49

BCM450 Hardware & Installation 52 NN40011-001 Issue 1.2 BCM450 Rls 6.0 8. Push the base function tray levers forward to the locked position. T

Page 50

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 53 11. Restore the BCM system to operation. 12. Observe the system sta

Page 51

BCM450 Hardware & Installation 54 NN40011-001 Issue 1.2 BCM450 Rls 6.0 7. The power supply module is located at the back of the unit, on the

Page 52

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 55 8. The power unit‘s cables are connected to the main chassis to pro

Page 53 - Replacing the Power Supply

BCM450 Hardware & Installation 56 NN40011-001 Issue 1.2 BCM450 Rls 6.0 11. Reconnect the power supply cables to the BCM‘s main unit. 12. Sec

Page 54

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 57 Replacing a Redundant Power Supply Module Should one of the Redundan

Page 55

BCM450 Hardware & Installation 58 NN40011-001 Issue 1.2 BCM450 Rls 6.0 7. Using the handle on the module, pull the module free of the cage.

Page 56

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 59 If the disk becomes faulty or is damaged, it can be replaced. Warn

Page 57

BCM450 Hardware & Installation 6 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Hardware & Installation Overview The BCM450 system is a complete, con

Page 58 - Removing the Hard Disk

BCM450 Hardware & Installation 60 NN40011-001 Issue 1.2 BCM450 Rls 6.0 7. On the bottom left of the front panel of the base function tray ther

Page 59

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 61 9. The hard disk bracket should be visible. The drive on the left i

Page 60

BCM450 Hardware & Installation 62 NN40011-001 Issue 1.2 BCM450 Rls 6.0 11. If the secondary hard drive (HDD-2) is being replaced, remo

Page 61

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 63 13. Remove the four screws that secure the hard disk to the

Page 62

BCM450 Hardware & Installation 64 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Installing the hard disk 1. Use Element Manager to shut down the BCM450

Page 63

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 65 6. Push the hard disk and bracket forward into the primary hard dis

Page 64 - Installing the hard disk

BCM450 Hardware & Installation 66 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Preparing the Multi-Image Hard Drive The Multi-Image Hard Drive field Re

Page 65

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 67 3. Login to the BCM using the default details:  User = nnadmin

Page 66

BCM450 Hardware & Installation 68 NN40011-001 Issue 1.2 BCM450 Rls 6.0 4. The Quick Configuration menu will display. Select 1 -> Install an

Page 67

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 69 6. When the hardware type has been detected, you will be presented

Page 68

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 7 The BCM450 hardware has the following primary components:  1 x Ded

Page 69

BCM450 Hardware & Installation 70 NN40011-001 Issue 1.2 BCM450 Rls 6.0 8. The selected software release will be applied to the hard drive, and

Page 70

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 71 Replacing the Random Access Memory (RAM) Card The RAM card can b

Page 71

BCM450 Hardware & Installation 72 NN40011-001 Issue 1.2 BCM450 Rls 6.0 7. Carefully push down on the holding clips positioned on either side o

Page 72

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 73 11. Carefully and firmly press down on the top of the DIMM card with

Page 73 - Replacing a Cooling Fan

BCM450 Hardware & Installation 74 NN40011-001 Issue 1.2 BCM450 Rls 6.0 5. The fan can be accessed by removing the panel cover located to the r

Page 74

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 75 7. Remove the fan‘s retention clips. This can be achieved by pushin

Page 75

BCM450 Hardware & Installation 76 NN40011-001 Issue 1.2 BCM450 Rls 6.0 10. Place the new fan in the BCM unit in the same position as the old fa

Page 76

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 77 16. Ensure that the fan is securely connected to the BCM chassis. 1

Page 77 - Replacing the Clock Battery

BCM450 Hardware & Installation 78 NN40011-001 Issue 1.2 BCM450 Rls 6.0 8. Carefully lift the battery out of its socket. Do not use any type o

Page 78

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 79 When the BCM450 is in the reset condition, further modifications can

Page 79 - BCM Command Line Interface

BCM450 Hardware & Installation 8 NN40011-001 Issue 1.2 BCM450 Rls 6.0  One DS256 jack to connect the BCM expansion unit to the BCM450 main ch

Page 80 - Maintenance CLI

BCM450 Hardware & Installation 80 NN40011-001 Issue 1.2 BCM450 Rls 6.0  Status of the power supply module(s), power supply fan(s), and chassi

Page 81

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 81 Accessing the BCM’s Command Line Interface via the Serial Po

Page 82

BCM450 Hardware & Installation 82 NN40011-001 Issue 1.2 BCM450 Rls 6.0 5. Configure the following settings, and click OK: o Bits per second:

Page 83

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 83 6. You will be presented with a Hyper Terminal window. 7. Ente

Page 84

BCM450 Hardware & Installation 84 NN40011-001 Issue 1.2 BCM450 Rls 6.0 8. Press the enter key. You will be presented with a login screen. 9

Page 85

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 85 10. Then enter the password PlsChgMe! or whatever the password has

Page 86

BCM450 Hardware & Installation 86 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Accessing the Command Line Interface Using PuTTY PuTTY is a software too

Page 87

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 87 4. Accept any further security messages that you may get p

Page 88

BCM450 Hardware & Installation 88 NN40011-001 Issue 1.2 BCM450 Rls 6.0 7. From the Applications list, select Other Administrator Applications

Page 89

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 89 11. Click on the Run button to install the application. 12. Clic

Page 90

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 9  Hard Disk: 80GB SATA located at front of unit for easy access 

Page 91

BCM450 Hardware & Installation 90 NN40011-001 Issue 1.2 BCM450 Rls 6.0 13. When installed, the PuTTY program will automatically launch. Enter t

Page 92 - Upgrading to BCM Rls 6.0

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 91 15. You will then be presented with the CLI. Make your selections as

Page 93 - Applying the Keycode File

BCM450 Hardware & Installation 92 NN40011-001 Issue 1.2 BCM450 Rls 6.0 Upgrading to BCM Rls 6.0 BCM450 Rls 1.0 or 5.0 can be upgraded to BCM450

Page 94

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 93 2. Check that the Time Zone field is set to your region, and is not

Page 95 - Performing the Upgrade

BCM450 Hardware & Installation 94 NN40011-001 Issue 1.2 BCM450 Rls 6.0 2. Click on the Load File button. 3. Browse to the location of the

Page 96

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 95 4. Click Open. 5. The new keycode file will be applied to the BC

Page 97

BCM450 Hardware & Installation 96 NN40011-001 Issue 1.2 BCM450 Rls 6.0 2. Click on the Get New Updates button to specify where the upgrade fil

Page 98

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 97 5. For the My Computer option (i.e. the upgrade files are stored on

Page 99 - Post-Upgrade Activities

BCM450 Hardware & Installation 98 NN40011-001 Issue 1.2 BCM450 Rls 6.0 8. Click Yes in the Confirm window. 9. The upgrade files will then

Page 100 - Avaya Documentation Links

BCM450 Hardware & Installation NN40011-001 Issue 1.2 BCM450 Rls 6.0 99 Applying the Factory Image When the BCM has been upgraded it is high