Alarm Code maintenance actions
1. Using Windows, and login to DMC DECT Manager. Select the system that supports
the DECT system. Launch the DECT application. Open the DECT Systems window.
Open the Current Alarms window.
Follow the instructions in:
• Logging into the DMC DECT Manager on page 229
• Selecting the PBX that supports DECT on page 230
• Launching the DECT application on page 187
2. Refresh the Alarm Snapshot window.
Click on the icon:
3. Examine the alarm code, and take the appropriate maintenance action.
See Alarm Code maintenance actions on page 268.
Note:
The Windows
Alarm Notification only displays alarms that have occurred since the window
was opened. The Web Alarm Browser has a circular log that provides information on a limited
history of alarms. The Web Alarm browser records alarms at all times.
Table 46: Alarms
Alarm code Alarm description Maintenance action
DMC8 operational state Synthesis
DCT001 All DMC8 cards are operational.
(DCT001 only displayed in the
Alarm
browsers. DCT001 does not show in
the Alarm Snapshot list.)
Information only, no action needed.
DCT002 At least one DMC8 card is not
operational. (DCT002 only displayed
in the Alarm browsers. DCT002 does
not show in the Alarm Snapshot list.)
Remove the DMC8 and insert the
DMC8 again to reboot. If the reboot
fails, replace the DMC8.
Note:
When at least one DMC8 card becomes inoperable, DCT002 appears in the alarm
browser history
. When all the DMC8 cards become operational again, DCT001 appears
in the browser history.
Presence of an alarm
DCT101 No alarms. (DCT101 only displayed
in the Alarm browsers).
Information only, no action needed.
Alarm Code maintenance actions
DMC DECT Fundamentals August 2012 269