VENGINE 28045
MESSAGE
[Para <block_name>/<1 >] Unresolved INVOKE <appname>
SEVERITY
3
PROBABLE CAUSE
The application attempted to link to another application but the other application does
not exist (or is not running). PeriProducer displays a warning for unresolved link
references during application generation, but still creates the application executable
(.vex) file.
ACTION
Either fix the linked application reference (if the linked reference is spelled incorrectly
or uses an invalid path) or create the linked application.