Page view 174
show bisync
2-123
disabled
Displays BISYNC circuits that a user has manually disabled.
Sample Display – show bisync disabled
BISYNC Modules Disabled:
----------------------
Line Media Char
Slot Conn Circuit State Number MTU Type Mode
---- ---- -------- -------- -------- ---- -------- --------
1 1 S11 Disabled 01591101 1580 DEFAULT EBCDIC
Found 1 match out of 1 entry in table.
For column definitions, see the alerts command.
enabled
Displays BISYNC circuits that a user has manually enabled.
Sample Display – show bisync enabled
BISYNC Modules Enabled:
---------------------
Line Media Char
Slot Conn Circuit State Number MTU Type Mode
---- ---- -------- -------- -------- ---- -------- --------
1 1 S11 Up 01501101 1580 DEFAULT EBCDIC
Found 1 match out of 1 entry in table.
For column definitions, see the alerts command.