Avaya P580 User Manual Page 694

  • Download
  • Add to my manuals
  • Print
  • Page
    / 764
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 693
Chapter 31
31-4 Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
set temperature (warning)
Command Mode Global Configuration.
Description Sets the warning temperature (in Celsius) for a specific component of the
switch. The default values are listed in
Table 31-3.
Syntax set temperature {supervisor-slot | backplane-sensor | cpu-sensor | probe}
warning {upper | lower | low-limit} <temperature>
Table 31-3. Default Warning Temperatures
Component Upper
Warning
Lower
Warning
Low Limit
CPU Sensor 85°
All others 60°
Table 31-4. Parameters, Keywords, Arguments
Name Definition
{supervisor-slot |
backplane-sensor |
cpu-sensor | probe}
Indicates which component of the switch you are setting
the temperature for.
Note: After you change the temperature settings for the
active supervisor, you must synchronize the active
and standby supervisors to copy the temperature
settings to the standby supervisor.
warning Required parameter indicating that a warning limit is
being modified.
1 of 2
Page view 693
1 2 ... 689 690 691 692 693 694 695 696 697 698 699 ... 763 764

Comments to this Manuals

No comments