Avaya 1000 Series Video Conferencing Systems Application Note Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 45
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
TJM Reviewed:
SPOC 12/01/2010
Solution Interoperability Lab Application Notes
©2010 Avaya Inc. All Rights Reserved.
12 of 45
SM6_CMFS6_10x0
2.8. Configure Stations
The method is the same for administering all of the Avaya 1000 series video endpoints with the
exception of the 1040 and 1050’s. The only difference is that the 1040 can be administered to
have up to 3 call appearances and the 1050 can have up to 7 call appearances for conferencing
via their internal MCU’s. The 1010, 1020, and 1030 have to be administered with only one call-
appearance since they are a single-line endpoint with no conferencing or transferring capabilities.
For each SIP user to be defined in Session Manager, add a corresponding station on the
Communication Manager Feature Server. Note: instead of manually defining each station using
the Communication Manager SAT interface, the preferred option is to automatically generate the
SIP station when adding a new SIP user. See Section 3.3.6 for more information on adding SIP
users.
The phone number defined for the station will be the number the SIP user enters to register to
Session Manager. Use the “add station x” command where x is a valid extension number
defined in the system. In this example extension 55002 is an Avaya 1020 video endpoint. On
page 1 of the change station form:
Phone Type: Set to 9630SIP
Name: Display name for user
Security Code: Number used when user logs into station. Note: this code
should match the “Shared Communication Profile
Password” field defined when adding this user in Session
Manager. See Section 3.3.6.
IP Video? Enable endpoint for video
add station 55002 Page 1 of 6
STATION
Extension: 55002 Lock Messages? n BCC: 0
Type: 9630SIP Security Code: 123456 TN: 1
Port: S00006 Coverage Path 1: 1 COR: 1
Name: SIL Video Lab - 1020 Coverage Path 2: COS: 1
Hunt-to Station:
STATION OPTIONS
Time of Day Lock Table:
Loss Group: 19
Message Lamp Ext: 55002
Display Language: english Button Modules: 0
Survivable COR: internal
Survivable Trunk Dest? y IP SoftPhone? n
IP Video? y