244 BSGX4e Business Gateway User Guide
NN47928-102 Release 01.01
This commands parameter is as follows:
Show Impedance Settings
To show the impedance setting, enter the following command:
> show voice fxs hw
FXS Global HW Settings:
Impedance Automatic
Electrical Status
To show the current electrical values for the FxS port, enter the following command:
> show voice fxs status
FXS Status:
Port Line State Battery (V) Line (V) Current (mA) Power (mW)
-------------------------------------------------------------
0-1 Ready 61 49 0 0
Parameter Description
impedance Specialized impedance override setting for the line
(automatic | 600 | 900 | 600_luF | 900_2.16uF |
270+750_150nF | 220+820_120nF | 220+820_115nF
| 200+680_100nF). The default is automatic.
Field Description
Port Unit and port number.
Line State The possible line states are:
Open-Cct Open Circuit.
Ready
Fwd-OHT Forward On-hook Transmission.
Tip-Open
Ringing
Rev-actionReverse Active.
Rev-OHT Reverse On-hook Transmission.
Ring-Open
Thermal
Failed
Battery Scaled battery voltage measurement in the range
0-327 Volts.