Avaya Using Technician Interface Scripts User Manual Page 287

  • Download
  • Add to my manuals
  • Print
  • Page
    / 849
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 286
show dsx3
117380-A Rev. A 2-243
current
[
<circuit name>
]
Displays the general circuit information in addition to current DS-3/E-3 information for
the specified circuit or for all circuits. For more information on column definitions, see the
ccts command.
The table displays the following information:
General Circuit Information
Circuit Name Name of the circuit associated with this line.
Index Line and line level identifier.
Sec into Interval The number of seconds into the current 15-minute interval.
# of Intervals The number of complete 15-minute intervals.
Line Coding The line coding on this circuit. The line coding options are
• B3ZS
• HDB3
Line Type The line type of this circuit. The options are
• DS3_M23 (ANSI T1.107-1988)
• DS3_Cbit (ANSI T1.107a-1989)
• E3_framed (CCITT G.751)
• E3_plcp (ETSI T/NA[91]18)
Status The line status of the interface. The possible status variables are
• NoAlarm - no alarm present
• RRAI - receiving yellow remote alarm indication
• TRAI -- transmitting yellow remote alarm indication
• RAIS - receiving Alarm Indications Signal (AIS) failure state
• TAIS - transmitting AIS failure state
• LOF - receiving Loss of Frame (LOF) failure state
• LOS - receiving Loss of Signal (LOS) failure state
• Loopback
- looping the received signal
• TestCode - receiving a test pattern
• LowSignal - low signal