Avaya Using Technician Interface Scripts User Manual Page 697

  • Download
  • Add to my manuals
  • Print
  • Page
    / 849
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 696
Using Technician Interface Scripts
2-650 117380-A Rev. A
Sample Display - show t1 line
T1 Module Line Errors:
----------------------
Yellow Red
BiPolar Alarms Carrier Alarms
Slot Conn Circuit Violtns Recvd Loss Recvd
---- ---- ------- ---------- ---------- ---------- ----------
2 1 T1-21 396177689 0 1 3
2 2 T1-22 396063622 0 4 0
2 entries in table.
BiPolar Violtns Number of bipolar violations on this line. On a T1 line, 1’s are
transmitted as alternating negative and positive pulses, and 0’s are
simply the absence of pulses. Thus a bipolar violation occurs if
there are two or more consecutive pulses of the same polarity. This
error count indicates the quality of the T1 line.
Yellow Alarms Rcvd Number of times the router has received a yellow alarm on this line.
A yellow alarm indicates that we have not lost sync, but the remote
side of the connection has detected a problem with this line.
Carrier Loss Number of instances of carrier loss detected on this line. This
typically occurs during cable removal.
Red Alarms Recvd Number of instances of out-of-frame errors detected for periods
exceeding 2.5 seconds; typically a mismatched framing format
causes this condition.
Page view 696
1 2 ... 692 693 694 695 696 697 698 699 700 701 702 ... 848 849

Comments to this Manuals

No comments

On Networks DSG008-199PES podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Switche sieciowe On Networks DSG008-199PES.
Dostarczamy 1 pdf podręczników On Networks DSG008-199PES do pobrania za darmo według typów dokumentów: Arkusz Danych






Więcej produktów i instrukcji dla Switche sieciowe On Networks

Modele Rodzaj dokumentu
DSF008 Dokumentacja   On Networks DSF008, 2 strony