Isolating Problems Using Loopback Data Tests
D-14
Loop-Around Data Test Arrangement
Setting Up a Loop-Around Data Test
Arrangement
The Loop-Around Data Test Arrangement does not require special switch
administration over and above the normal switch administration procedure for
the 8400B Plus Data Module.
If the Loop-Around Data Test Arrangement is being used to test modem pools
(see Figure D-7
), separate 8400B Plus Data Modules must be set up for each
modem pool group to be tested. Separate telephone numbers should be
administered for the Loop-Around Data Test Arrangements used for modem
pool testing.
The 8400B Plus Data Module must be connected to the PBX and powered up
prior to using it in the Loop-Around Data Test Arrangement. Connect an
asynchronous data terminal to the 8400B Plus Data Module using the standard
EIA Connector cord and supplied M9/F25 Adapter. The speed of the terminal
should be set as indicated in Table D-1
.
Once the data rate has been set on the terminal, type the following command:
AT&FS0=1E0Q1&W0&W1
Table D-1. Setting Data Terminal Speed
Access Set Terminal Data Rate To
Direct 19200 bps
Through a modem pool that supports
speeds of:
■ 300 and 1200 bps
■ 300, 1200, and 2400 bps
■ 1200, 2400, 4800, and 9600 bps
■ 4800 and 9600 bps
1200 bps
2400 bps
9600 bps
9600 bps
ENTER