Cable Guide
6-12 114072-A Rev. C
44-Pin to RS-530 Straight-through (Order No. AA0018012)
Industry Interface Type: RS-530
Bay Networks Termination Remote Termination
Signal Pin # to Pin # Signal
Send Data + 2 2 Transmitted Data A
Send Data - 16 14 Transmitted Data B
Receive Data + 3 3 Receive Data A
Receive Data - 17 16 Receive Data B
Request to Send + 4 4 Request to Send A
Request to Send - 18 19 Request to Send B
Clear to Send + 5 5 Clear to Send A
Clear to Send - 19 13 Clear to Send B
Data Set Ready + 6 6 DCE Ready A
Data Set Ready - 20 22 DCE Ready B
Data Terminal Ready + 8 20 DTE Ready A
Data Terminal Ready - 22 23 DTE Ready B
Data Carrier Detect + 9 8 Receive Line Signal Detect A
Data Carrier Detect - 23 10 Receive Line Signal Detect B
Send Timing + 10 15 Transmitter Signal Element Timing
(DCE) A
Send Timing - 24 12 Transmitter Signal Element Timing
(DCE) B
15 ft
(4.57 m)
Pin 1
Pin 16
Pin 31
Pin 15
Pin 30
Pin 44
44-position D-sub plug with screw locks
(ground shield connected to backshell)
Pin 13
Pin 1
Pin 25
Pin 14
25-position D-sub plug with screw locks
(ground shield connected to backshell)
CAB0094A