Avaya Cable User Manual Page 82

  • Download
  • Add to my manuals
  • Print
  • Page
    / 202
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 81
Cable Guide
5-20 114072-A Rev. C
MCE1 Straight-through Cable (Order No. 7161)
Industry Interface Type: E1/G.703
Bay Networks Termination Remote Termination
Signal Pin # to Pin # Signal
Receive A (RXA) 1 1 Receive A (RXA)
Receive B (RXB) 6 6 Receive B (RXB)
Transmit A (TXA) 5 5 Transmit A (TXA)
Transmit B (TXB) 9 9 Transmit B (TXB)
Internal Wire Connections
Pin 3 (Shield) Pin 3 (Shield grounded to backshell)
10 ft
(3.05 m)
Pin 1
Pin 9
9-position D-sub plug with screw locks
(ground shield connected to backshell)
Pin 1
Pin 9
9-position D-sub plug with screw locks
(ground shield connected to backshell)
CAB0033A