Cable Guide
5-16 114072-A Rev. C
MCT1 Loopback Cable (Order No. 7155)
Industry Interface Type: T1/DS1
Bay Networks Termination Remote Termination
Signal Pin # to Pin # Signal
Transmit Tip 1 3 Receive Tip
Receive Tip 3 1 Transmit Tip
Transmit Ring 9 11 Receive Ring
Receive Ring 11 9 Transmit Ring
15 ft
(4.57 m)
Pin 8
Pin 1
Pin 15
Pin 9
Pin 8
Pin 1
Pin 15
Pin 9
15-position D-sub plug with locking posts
(ground shield connected to backshell)
15-position D-sub plug with locking posts
(ground shield connected to backshell)
CAB0027A