Chapter 9 Connecting the cables to the BCM50 system 107
Installation and Maintenance Guide
Figure 51 Connect a UPS
If your BCM50 system does not have a UPS, continue with the procedure To connect a power
supply without a UPS on page 107.
To connect a power supply using a UPS
1 Mount the UPS within 1.5 meters (5 ft.) of the BCM50 units.
The UPS must be close enough to the BCM50 units that you can connect the power supply to
both the UPS and the BCM50 units.
2 Plug one end of the USB cable into the USB port on the UPS.
For information about the location of the ports on the UPS, see the UPS documentation.
3 Plug the other end of the USB cable into the USB hub.
4 Plug one end of the second USB cable into the USB hub.
5 Plug the other end of the second USB cable into the USB port on the main unit.
6 Plug the UPS power cord into the AC power source (wall outlet).
7 Proceed to Connecting the lines and extensions on page 108.
To connect a power supply without a UPS
1 Unpack the new power supply.
2 Check the power supply for damage. If you find damage, contact your Nortel representative.
3 Rotate the retention clip so the power outlet is open.
4 Plug the power supply cord into the BCM50 unit.
Warning: Do not use the power supply if the power supply cord or power supply
cable is damaged.
Note: Use only the power supply that is approved by Nortel for use with the BCM50
units.
Main unit
Power supply
USB hub
UPS
USB cable