T1/FT1 Adapter Module
Supplement
1-4
118943-B Rev 00
Completing Software Configuration
Once you have successfully installed the adapter module, complete the following
software configuration tasks using instructions found in your BayRS
documentation:
For the latest information, be sure to review the release notes and documentation
change notice for your version of BayRS software.
Interpreting LEDs
The T1/FT1 adapter module LEDs (Figure 1-4) will blink on and off during
diagnostic testing, but they will not stay on to indicate data transfer until you have
configured and enabled T1/FT1 software services.
Figure 1-4. T1/FT1 Adapter Module LEDs
Configuration Task Location of Instructions
Connect the AN/ANH to the network.
Note that you cannot perform a Netboot or
Directed Netboot operation using the
T1/FT1 adapter module interface.
The boot/startup methods you can use are
Local Boot and EZ-Install.
One of the following:
• Installing and Operating BayStack AN
and ANH Routers
• Configuring BayStack Remote Access
Modify the configuration file to add the T1/
FT1 module and enable default software
services.
One of the following:
• Configuring and Managing Routers with
Site Manager
• Using the Bay Command Console
(BCC)
Configure T1 or FT1 services.
Configuring WAN Line Services
Red Alm
Yel Alm
Loop
Sync
ARN0106A
T1/FT1
DSU/CSU
Comments to this Manuals