Configuring ATM Services
314470-15.2 Rev 00
1-3
For example, the following command changes the clear alarm threshold from 2 to
8 seconds:
atm-e3/1/1/2/1#
clear-alarm-threshold 8
atm-e3/1/1/2/1#
Specifying the Line Coding Method
To specify the line coding method, navigate to the ATM interface prompt (for
example,
box
;
atm/1/1/2/1
;
atm-e3
) and enter:
line-coding {hdb3
|
b3zs}
The default for the ATM E3 interface is hdb3 and the default value for the ATM
T3 interface is b3zs.
Specifying the Line Type
To specify the line type for this interface, navigate to the ATM interface prompt
(for example,
box
;
atm/1/1/2/1
;
atm-e3
) and enter:
line-type <type>
type
is autodetect, ds3m23, or ds3cbitparity for the ATM T3 interface and
e3framed or e3plcp for the ATM E3 interface.
If the line type is ds3m23, the framing mode should be m23 or t3m23plcp.
If the line type is ds3cbitparity, the framing mode should be cbit or t3cbitplcp.
If the line type is either e3framed or e3plcp, the framing mode should be either
g751or g832.
For instructions on setting the framing-mode parameter, see Configuring ATM
Services.
Specifying the Loopback Mode
To force the interface into loopback mode so that the far-end or intermediate
equipment can perform diagnostics on the network between that equipment and
the T3/E3 interface, navigate to the ATM interface prompt (for example,
box
;
atm/1/1/2/1
;
atm-e3
) and enter:
loopback-mode <type>