Site Manager Parameters
314470-15.2 Rev 00
A-7
Parameter: Framing Mode
Path: Configuration Manager > ATM1 > ATM Line Attributes
Default: DS3_CBIT (for DS3 lines)
|
E3_G832 (for E3 lines)
|
T1ADM (for DS1 lines)
|
E1ADM (for E1 lines)
Options: DS3_CBIT
|
DS3_M32
|
T3CBITTPLCP
|
T3M23PLCP
|
E3_G751
|
E3_G832
Function: Specifies the transceiver mode for the physical interface.
Instructions: Select a transceiver mode as follows:
• DS3_CBIT, DS3_M32, T3CBITTPLCP, or T3M23PLCP for DS3 modules
• E3_G751 or E3_G832 for E3 modules
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.3.2.1.17
Parameter: Cell Scrambling
Path: Configuration Manager > ATM1 > ATM Line Attributes
Default: Off
Options: On
|
Off
Function: If you select On, the router randomizes cell payload sufficiently to guarantee
cell synchronization. If you select Off, cell synchronization problems can occur.
Note that ATM devices with different settings for scrambling cannot
communicate. For example, if you configure a router to enable scrambling and
configure a hub to disable scrambling, the router and the hub cannot
communicate.
Instructions: If you select On, be sure to enable scrambling for all devices on the network. If
you select Off, be sure to disable scrambling for all devices on the network.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.3.2.1.22