Using Site Manager
To create an ATM circuit for a T3 or E3 connection on a Passport 5430, complete
the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM DS3/E3 interface (ATM1)
in slot 1, PCI slot 1, module 2.
The Add Circuit window opens.
2. Click on OK to accept the default circuit
name.
The ATM Configuration window opens.
3. Click on Physical Layer Configuration. The Physical Layer Configuration window
opens.
4. Click on either DS3 or E3. The Port Parameters window opens.
5. To configure port parameters, set the
following parameters as needed:
• Enable/Disable
•Line Type
• Setup Alarm Threshold (seconds)
• Clear Alarm Threshold (seconds)
• Loopback Configuration
•Primary Clock
Click on Help or see the parameter
descriptions in “
ATM Port Parameters,”
beginning on page A-2
.
6. Click on OK. The Physical Layer Configuration window
opens.
7. Click on Done. The ATM Configuration window opens.
8. Click on ATM Line Attributes. The ATM Line Driver Attributes window
opens.
(continued)