4. For Analog Trunks, set the Trunk Type to Out of Service.
5. For BRI, E1 PRI, S0 and QSIG Trunks, set the channels quantities to match the
actual subscribed channels.
6. For T1, T1 PRI and E1R2 Trunks, select the Channels tab. Then do the following:
Select those channels that are not used and click Edit.
• For T1 set the Type to Out of Service
• For T1 PRI set the Admin field to Out of Service.
• For E1R2 trunks set the Line Signalling Type to Out of Service.
7. Select File > Save Configuration.
Digital trunk clock source
About this task
Digital trunks require the telephone system at each end of the trunk to share a clock signal to
ensure synchronization of call signalling. The B5800 Branch Gateway can obtain and use the
clock signal from any of its digital trunks. Typically the clock signal provided by a digital trunk
from the central office exchange is used as this will be the most accurate and reliable clock
source.
To do this, the Clock Quality setting on each line in the B5800 Branch Gateway configuration
is set to one of the following:
Network
If available, the clock signal from this trunk should be used as the B5800 Branch Gateway
clock source for call synchronization. If several trunk sources are set as Network, the
B5800 Branch Gateway will default to using one as detailed below.
Fallback
If available, the clock signal from this trunk can be used as the clock source if none of the
trunks set as Network are providing a clock source.
Unsuitable
The clock source from this trunk will never be used as the B5800 Branch Gateway clock
source.
If no clock source is available the B5800 Branch Gateway can use its own internal clock if
necessary.
In the example below the first B5800 Branch Gateway is set to use the public network trunk
as its clock source and ignoring the possible clock source from the QSIG trunk. The other
B5800 Branch Gateway system is using the clock signal received from the first B5800 Branch
Digital trunk clock source
Implementing the Avaya B5800 Branch Gateway for an Avaya Aura
®
Configuration October 2012 135