Chapter 11 Installing the analog terminal adapter 125
BCM50 Installation and Maintenance Guide
Figure 56 ATA2 pin outs
To connect the ATA2
1 Connect one end of a line cord to the ATA2 terminal jack.
2 Connect the other end to your telephone, modem, or fax.
3 Connect one end of a line cord to the ATA2 line jack.
4 Connect the other end to an available station port on the BCM50 system.
5 For a 120 V or 230 V system, plug the DIN connector of the power supply cord into the power
supply connector receptacle. Plug the adapter into a standard AC outlet.
Mounting the ATA2
After the ATA2 is correctly connected, you can mount the unit on a wall as described in this
section.
To mount the ATA2 on a wall
1 When using 0.5 mm wire (24-AWG), select a location within 800 m (2600 ft.) of the BCM50.
2 Allow 12.5 cm (5 in.) clearance for the line jack, terminal jack, and power supply connector.
3 Screw two 4-mm (#8) screws into the wall 130 mm (5.25 in.) apart. Leave 6 mm (0.25 in.) of
the two screws showing.
4 Align the slots at the back of the ATA2 unit over the screws. Push the unit against the wall.
The line jack, terminal jack, and power supply connector must be at the top of the ATA2. See
the figure ATA2 back view on page 126.
Caution: In North America, the ATA2 must be powered from a Class 2 power source that
is UL- and CSA-approved.
In Europe, the ATA2 must be powered from a Class II power source that is CE marked.
TCM*
TCM*
Ring (B-Lead)
Tip (A-Lead)
Line jack
Terminal jack
* The TCM input is not polarity sensitive.