Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, v5.3.1 7-11
Configuring Redundancy Options
Using the Web
Agent
To enable the replacement element using the Web Agent:
1. Select Switch Fabric from the System> Configuration
group on the Web Agent window. The Switch Fabric
Status dialog box opens (Figure 6-21).
2. Select Yes from the Configure Redundant Hardware field
pull-down menu.
3. Click APPLY to enable the redundant element.
The Switch Elements field displays:
Normal # 0
This indicates that the redundant element is now enabled.
4. Save the configuration changes
Using the CLI To enable an element using the CLI, enter the following command
from Configure mode:
> set fabric configure-redundant-hardware enable
Refer to the Command Reference Guide for the Avaya P550R, P580, P880,
and P882 Multiservice Switches, v5.3.1 for more details about this
command.
Configuring Supervisor Module Redundant
Ethernet Console IP Addresses
Using the Web
agent
If you need to communicate with both the Active and Standby
Supervisors, configure an alternate Ethernet Console IP address for
both. Configure an alternate IP address for both slot 1 and 2 CPU’s,
by using the Web Agent or the CLI.
* Note: Do not Login to a Standby Supervisor module to manage
the switch. The Standby Supervisor does not have
accurate switch status information until it becomes the
Active Supervisor.
Identifying the Active or Standby supervisor can be
accomplished by looking at the LED display (marquee),
or by opening the System>Configuration>CPU
Redundancy>Status/Statistics group from the web
agent, or by using the show CPU status CLI
command.