Voice Commands 3 Configuration commands
176 NN47928-107
voice fxo hw impedance
This command sets a line impedance value for the FXO port(s).
Syntax config voice fxo hw impedance [automatic
600|900|270+750_150nF|220+820_120nF|370+620_310nF|320+1150_23
0nF|370+820_110nF|275+780_115nF|120+820_110nF|350+1000_210nF|
200+680_100nF|600_2.16uF|900_1uF|900_2.16uF|600_1uF] acim
<value> hyb1-8 <filter>
Parameters impedance automatic|600|900|600_1uF|900_2.16uF|270+750_150nF|
220+820_120nF|370+620_310nF|320+1150_230nF|370+820_110nF|
275+780_115nF|120+820_110nF|350+1000_210nF|200+680_100nF|
600_2.16uF|900_1uF|900_2.16uF|600_1uF
Enter the impedance. It overrides the settings
of the line(s). The default is automatic.
acim value Specify an AC impedance register (customizing
impedance only). The value refers to an AC line
termination. The default value is 11 (600 W +
2.16 mF).
hyb1-8 filter Specify a hybrid filter. Eight hybrid filters are
provided (for customizing impedance only).
Valid values are 0 - 255. The default value for
each filter is 0.