Beginning in B5800 Branch Gateway R6.2, you have the option to leave the Branch Prefix field
blank. If you do not configure the Branch Prefix, the native extensions must be defined with
the full enterprise number. You are also able to leave the Local Number Length field blank.
By default B5800 Branch Gateway systems use 3-digit extension numbering starting from 200.
The existing allocated numbers can be changed in bulk using the Tools > Extension
Renumber option. This will add or remove a set value from all existing extension numbers in
the configuration.
Procedure
1. From the System Manager console, select the B5800 Branch Gateway device and
click Edit to edit the system configuration for the device. IP Office Manager will be
launched on your PC. For more information, see
Editing a B5800 Branch Gateway
system configuration from System Manager on page 159.
2. In the left navigation pane, click System.
3. Click the System tab.
4. Set the following fields as appropriate:
• Branch Prefix (optional)
• Local Number Length (optional)
• Proactive
• Reactive
These 4 fields are the key settings for B5800 Branch Gateway operation. See
System tab field descriptions on page 142 for more information.
5. Click OK.
6. Select File > Save Configuration.
The Send Configuration window appears and the Configuration Reboot Mode is set
to Immediate. Do not change the reboot mode.
System tab field descriptions
Name
Range or Default Description
Branch Prefix Range = 0 to 999999999 This number is used to
identify the B5800 Branch
Gateway system within the
Avaya Aura
®
network. The
branch prefix of each B5800
Branch Gateway system
must be unique and must not
overlap. For example 85, 861
Initial branch configuration
142 Implementing B5800 Branch Gateway for a CS 1000 Configuration October 2012