Castlerock SNMPc 5.1.6c and earlier
Procedure
1. Copy the following MIB files to the application's MIB folder. This folder is typically
C:\Program Files\SNMPc Network Manager\mibfiles.
MIB file Source
ENTITY-MIB \AdminCD\snmp_mibs\Standard on
B5800 Branch Gateway Admin DVD.
AVAYAGEN-MIB.mib \AdminCD\snmp_mibs\IPOffice on
B5800 Branch Gateway Admin DVD.
IPO-PROD-MIB.mib \AdminCD\snmp_mibs\IPOffice on
B5800 Branch Gateway Admin DVD.
IPO-MIB.mib \AdminCD\snmp_mibs\IPOffice on
B5800 Branch Gateway Admin DVD.
INET-ADDRESS-MIB.mib \AdminCD\snmp_mibs\Standard on
B5800 Branch Gateway Admin DVD.
INTEGRATED-SERVICES-MIB \AdminCD\snmp_mibs\Standard on
B5800 Branch Gateway Admin DVD.
DIFFSERV-DSCP-TC.mib \AdminCD\snmp_mibs\Standard on
B5800 Branch Gateway Admin DVD.
DIFFSERV-MIB.mib \AdminCD\snmp_mibs\Standard on
B5800 Branch Gateway Admin DVD.
IPO-PHONES-MIB.mib \AdminCD\snmp_mibs\IPOffice on
B5800 Branch Gateway Admin DVD.
2. In SMNPc select Config > MIB Database.
3. Select Add and select the MIB files listed above in the order listed.
Castlerock SNMPc V5.0.1
Procedure
1. Copy all of the B5800 Branch Gateway MIBs and standard MIBs from the B5800
Branch Gateway Administrator Applications DVD to the SNMPc mibfiles directory.
2. In the SNMPc mibfiles directory open the files STANDARD.mib and SNMPv2-
SMI.mib in Notepad.
SNMP
Implementing B5800 Branch Gateway for a CS 1000 Configuration October 2012 229