BCM50 System Start Up
NN40010-318 Issue 1.2 BCM50 Rls 6.0 45
Attribute
Value
Module/line type
Number
Length
This number allows the system to determine how many digits to read on an incoming call
to determine that the call is meant for this system.
Maximum
Transits
Default: 31
PRI
Indicate the maximum number of times that a call will be transferred within the SL-1
network before the call is dropped. Protocol must be set to SL-1 to display this field.
T1 parameters
CO fail
T1
PRI
Specify a carrier failure standard (T1A-5474, TR62411)
Interface
levels
ISDN, PSTN
T1
PRI
Define a loss plan setting.
Framing
ESF, SF
T1
PRI
Select the framing format used by your T1 or PRI service provider: Extended Superframe
(ESF) or Superframe (SF). Contact your T1 or PRI service provider for the proper setting.
(SF or Superframe is sometimes known as D4.)
Line coding
B8ZS, AMI
T1
PRI
Define the encoding signals on a T1 line. Select the standard used by your T1 service
provider. Contact your T1 service provider for the proper setting.
Internal
CSU
<check box>
T1
PRI
Turn the internal T1 channel service unit (CSU) on or off.
CSU line
build
0, 7.5, or 15 dB
T1
PRI
Set the gain level of the transmitted signal. This setting appears only when the Internal
CSU is Enabled.
DSX1 build
000-100, 100-
200, 200-300,
300-400, 400-
500, 500-600, or
600-700 feet
T1
PRI
Set the distance between BCM and an external channel service unit. This setting only
appears when the Internal CSU is Disabled. Contact your service provider for the proper
settings.
CRC4
<check box>
E1
PRI
Ensure this is enabled or disabled to match the service provider Cyclic Redundancy
Check (CRC4) setting for the trunk.