Configuring X.25 Services
4-32 117377-A Rev. A
Parameter: Max Connections
Default: 2
Options: 1 to 4
Function: Specifies the maximum number of virtual circuits that the router can
establish with the remote device specified in this record. Increasing the
number of connections to the same destination may improve the rate of
data throughput.
To take advantage of multiple virtual connections and load sharing across
them, set this parameter to a value greater than 1. This parameter has
meaning only for PDN services.
Instructions: Accept the default, 2, or enter a value within the specified range.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.2.1.15
Parameter: Precedence
Default: OFF
Options: ON
| OFF
Function: Specifies the priority of IP packets that this X.25 interface transmits and
that traverse the X.25 network. This parameter has meaning only for
DDN services.
Instructions: To enable IP packet prioritization, set Precedence to ON.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.2.1.16
Comments to this Manuals