Editing X.25 Parameters
117377-A Rev. A 4-13
Parameter: T1 Timer
Default: 60
Options: 1 to 999 seconds
Function: Specifies how long the router waits to receive an acknowledgment of a
transmitted command frame. Specifically, the T1 timer sets, in seconds,
the timeout values for Restart, Reset, and Clear commands. The router
uses this timer to set up data links.
Instructions: We recommend that you accept the default value, 60.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.5.1.32
Parameter: T2 Timer
Default: 180
Options: 1 to 999 seconds
Function: Specifies the call-confirmation timeout value in seconds. The value for
this timer is the amount of time the router has to respond to a
call-confirmation condition. This timer represents the ITU-T (formerly
CCITT) T11 timer for the DCE and the T21 timer for the DTE.
Instructions: We recommend that you accept the default value, 180.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.5.1.33
Parameter: T3 Timer
Default: 200
Options: 200 to 2000 milliseconds
Function: Specifies the congestion or busy condition watchdog timeout value in
milliseconds. The value for this timer is the length of time the router has
to respond to a congestion or busy condition.
Instructions: We recommend that you accept the default value, 200.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.5.1.34
Caution: We recommend that you accept the default T1 Timer, T2 Timer,
T3 Timer, and T4 Timer values. Reset these parameters with caution.
Comments to this Manuals