Editing X.25 Parameters
117377-A Rev. A 4-19
Parameter: Reverse Charge Accept
Default: OFF
Options: ON
| OFF
Function: Enables or disables the reverse charge accept facility on this interface.
When you enable this parameter, the router can accept calls with the
reverse charge facility.
Instructions: To enable the reverse charge accept facility, set this parameter to ON.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.5.1.20
Parameter: Fast Select
Default: OFF
Options: ON
| OFF
Function: Enables the fast select request facility on this interface.
When you enable this parameter, call request packets the router generates
and transmits on this interface can contain up to 128 bytes of user data.
Instructions: To enable the fast select request facility, set this parameter to ON.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.5.1.21
Parameter: Reverse Charging
Default: OFF
Options: ON
| OFF
Function: Enables or disables the reverse charge request facility on this interface.
Packet network charges accrue whenever the router generates an outgoing
call request packet. When you enable this parameter, these packet
network charges are charged to the receiving DTE.
Instructions: To enable the reverse charge request facility, set this parameter to ON.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.5.1.22
Note: When this parameter is set to ON, the router accepts calls with the
reverse charge facility, but it does not maintain a record of the charges.