Editing X.25 Parameters
117377-A Rev. A 4-9
Parameter: Default Tx/Rx Window Size
Default: 2
Options: 1 to 7 (for MOD8) or 1 to 127 (for MOD128)
Function: Specifies a default window size for this packet layer.
The value in this parameter applies only if the Flow Control Negotiation
parameter is set to OFF in both the packet level and service record
parameters.
Instructions: To specify a window size other than 2, enter a value within the specified
range.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.5.1.42
Parameter: Default Tx/Rx Pkt Length
Default: 128
Options: 16
| 32 | 64 | 128 | 256 | 512 | 1024 | 2048 | 4096
Function: Specifies a default packet size for this packet layer.
The value in this parameter applies only if the Flow Control Negotiation
parameter is set to OFF.
Instructions: To specify a nonstandard default packet size, set to one of the available
options.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.4.5.1.43
Note: The following parameters require you to specify logical channel
number (LCN) value ranges for SVCs. Each SVC channel you configure on
the router must have a unique LCN. There are three types of SVC channels:
incoming, bidirectional, and outgoing. You must configure at least one SVC
channel for X.25 to establish calls. The total number of channels you configure
cannot exceed 512.