Avaya Event Messages for Routers User Manual Page 123

  • Download
  • Add to my manuals
  • Print
  • Page
    / 928
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 122
Event Messages (ACE through ATMINTF)
303550-A Rev 00
2-77
Entity Code/Event Code 49/27
Decimal Identifier 16789787
Severity: Warning
Message: Line <line_no.> LLIndex <low_level_index>: No extended address bit in atm dxi header.
Meaning: The ATM DXI code has dropped a packet because of a mismatch between the setting of
the extended address bit and the actual length of the address contained in the packet.
Entity Code/Event Code 49/28
Decimal Identifier 16789788
Severity: Warning
Message: Line <line_no.> LLIndex <low_level_index>: Pkt length error- <SHORT/LONG>.
Meaning: A received frame has been rejected because it was either less than six characters long
(short) or longer than the maximum allowed frame size for the current media (long).
Entity Code/Event Code 49/29
Decimal Identifier 16789789
Severity: Warning
Message: Line <line_no.> LLIndex <low_level_index>: Unsupported control
(<rcvd_control_value>) on PVC <VPI_ID>/<VCI_ID>.
Meaning: The specified virtual path/virtual circuit received an unknown or unsupported Control
field. The received control value must be the same as the value defined by RFC 1294.
Action: Check the configuration of the ATM interface or the ATM PVC. Verify that both endpoints
have the same configuration.
Entity Code/Event Code 49/30
Decimal Identifier 16789790
Severity: Warning
Message: Line <line_no.> LLIndex <low_level_index> -- CS_PDU length mismatch on ATM PVC
<VPI_ID>/<VCI_ID>.
Meaning: A Convergence Sublayer Packet Data Unit (CS_PDU) has been discarded, because a
comparison of the header BASize field, the Trailer Length field, and the actual length of
the CS_VCI_PDU showed a mismatch.
Page view 122
1 2 ... 118 119 120 121 122 123 124 125 126 127 128 ... 927 928

Comments to this Manuals

No comments