Event Messages for Routers
8-4
303550-A Rev 00
Entity Code/Event Code 24/3
Decimal Identifier 16783363
Severity: Warning
Message: Circuit record is disabled on circuit <circuit_no.>.
Meaning: SMDS has been disabled on the specified circuit.
Action: Reset the Enable parameter to restore SMDS service.
Entity Code/Event Code 24/4
Decimal Identifier 16783364
Severity: Warning
Message: Circuit <circuit_no.> SMDS address is of incorrect length.
Meaning: An SMDS address entered on the specified circuit using the Technician Interface is of
improper length.
Action: Correct the address.
Entity Code/Event Code 24/5
Decimal Identifier 16783365
Severity: Warning
Message: Circuit <circuit_no.> SMDS address is of incorrect type.
Meaning: An SMDS address entered on the specified circuit using the Technician Interface is of the
incorrect type. That is, an individual address has been entered as a group address, or a
group address has been entered as an individual address.
Action: Correct the address.
Note:
This message should not appear if you have configured SMDS using
Site Manager, because Site Manager checks SMDS addresses for format and
length.
Note:
This message should not appear if you have configured SMDS using
Site Manager, because Site Manager provides formatting for group and
individual addresses.