Event Messages (SDLC through SWSERV)
303550-A Rev 00
8-69
Entity Code/Event Code 58/156
Decimal Identifier 16792220
Severity: Info
Message: Demand Circuit <circuit_no.> Min Duration Timer modified to <no.>.
Meaning: You have changed the value of the Minimum Call Duration parameter for this demand
circuit.
Entity Code/Event Code 58/157
Decimal Identifier 16792221
Severity: Info
Message: Demand Circuit <circuit_no.> Inactivity Mode modified.
Meaning: You have modified the value of the Inactivity Mode parameter for this demand circuit.
Entity Code/Event Code 58/158
Decimal Identifier 16792222
Severity: Info
Message: Line Manager terminating.
Meaning: The line manager is no longer active.
Entity Code/Event Code 58/161
Decimal Identifier 16792225
Severity: Info
Message: Resolved wfSwservInPhone NumCct to circuit <circuit_no.>
Meaning: The router determined the circuit number requesting a callback by matching the incoming
phone number with the numbers in the incoming phone list.
Entity Code/Event Code 58/162
Decimal Identifier 16792226
Severity: Info
Message: Signaling PPP to initiate Callback
Meaning: The circuit is configured for callback and the server notifies PPP to call back the client.