Avaya Event Messages for Routers User Manual Page 267

  • Download
  • Add to my manuals
  • Print
  • Page
    / 928
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 266
Event Messages (BGP through EGP)
303550-A Rev 00
3-79
Entity Code/Event Code 4/15
Decimal Identifier 16778255
Severity: Trace
Message: Adjacency Down Circuit <circuit_no.>, Adjacency=<area>.<node>, Sync lost
Meaning: The adjacent node whose address is <area>.<node> (previously accessible through the
specified circuit) is down because of circuit failure.
Action: Investigate and repair the cause of the circuit failure.
Entity Code/Event Code 4/17
Decimal Identifier 16778257
Severity: Trace
Message: Adjacency Down Circuit <circuit_no.>, Adjacency=<area>.<node>, Dropped
Meaning: The adjacent node whose address is <area>.<node> (previously accessible through the
specified circuit) has been dropped, because it transmitted a faulty hello packet.
Entity Code/Event Code 4/19
Decimal Identifier 16778259
Severity: Trace
Message: Adjacency Down Circuit <circuit_no.>, Adjacency=<area>.<node>, Address change
Meaning: The adjacent node whose address is <area>.<node> (previously accessible through the
specified circuit) has been declared down because of a type change (that is, from a
non-routing to a routing node, or vice versa).
Entity Code/Event Code 4/21
Decimal Identifier 16778261
Severity: Trace
Message: Adjacency Down Circuit <circuit_no.>, Adjacency=<area>.<node>, Timeout
Meaning: The adjacent node whose address is <area>.<node> (previously accessible through the
specified circuit) is down, because the router failed to receive three consecutive hello
packets from the adjacency.
Page view 266
1 2 ... 262 263 264 265 266 267 268 269 270 271 272 ... 927 928