Avaya Event Messages for Routers User Manual Page 340

  • Download
  • Add to my manuals
  • Print
  • Page
    / 928
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 339
Event Messages for Routers
4-12
303550-A Rev 00
Entity Code/Event Code 8/92
Decimal Identifier 16779356
Severity: Warning
Message: Node <FDDI_connector_no.> aborting init. Wrong Net Module type in Module
location<no.>.
Meaning: Either the type of network module in this location or the configuration is incorrect.
Action: Insert the correct type of network module or correct the configuration.
Entity Code/Event Code 8/93
Decimal Identifier 16779357
Severity: Warning
Message: Node <FDDI_connector_no.> aborting init. Net Module<no.> diag failed
(status=0x<status_code>).
Meaning: The net module identified by Net Module<no.> has failed. The status code indicates the
type of failure.
Action: Replace the network module as soon as possible. If you do not have a spare network
module now, but you have a spare connector on the existing network module:
Switch the cable associated with the failed circuit to the spare connector.
Configure a new, identical circuit.
Delete the failed circuit from the configuration.
Using the spare connector is a temporary measure. When you return the network module
to Bay Networks, be sure to report the <status_code> and the connector associated with
the failure.
Info Events
Entity Code/Event Code 8/26
Decimal Identifier 16779289
Severity: Info
Message: Service initializing.
Meaning: FDDI is initializing.