Event Messages (SDLC through SWSERV)
303550-A Rev 00
8-3
Entity Code/Event Code 74/5
Decimal Identifier 16796165
Severity: Info
Message: SDLC Service down on circuit <circuit_no.>.
Meaning: An SDLC interface has gone down on a circuit.
SMDS Events
The Switched Multimegabit Data Service, referred to as the SMDS entity, issues
the following event messages. The entity code assigned to SMDS events is 24.
Fault Event
Entity Code/Event Code 24/1
Decimal Identifier 16783361
Severity: Fault
Message: System error, service attempting restart.
Meaning: SMDS experienced a fatal error and is restarting automatically. SMDS will attempt to
restart up to five times.
Action: Verify that the configuration is correct. Call the Bay Networks Technical Solutions Center
if SMDS fails to restart.
Warning Events
Entity Code/Event Code 24/2
Decimal Identifier 16783362
Severity: Warning
Message: Circuit record does not exist for circuit <circuit_no.>.
Meaning: SMDS has not been configured on the specified circuit.
Action: Configure SMDS on the circuit.