Avaya Event Messages for Routers User Manual Page 295

  • Download
  • Add to my manuals
  • Print
  • Page
    / 928
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 294
Event Messages (BGP through EGP)
303550-A Rev 00
3-107
Entity Code/Event Code 63/17
Decimal Identifier 16793361
Severity: Warning
Message: Connector COM <connector_no.> Remote alarm indication failure.
Meaning: The remote end of the specified MCT1 port has detected an unframed, all-ones bit pattern
in the received data stream and issued an Alarm Indication Signal (AIS), or Yellow Alarm.
The remote end clears the AIS condition after receiving a properly framed bit stream.
Entity Code/Event Code 63/18
Decimal Identifier 16793362
Severity: Warning
Message: Connector COM <connector_no.> failure cleared.
Meaning: MCT1 has cleared a previously generated alarm.
Entity Code/Event Code 63/23
Decimal Identifier 16793367
Severity: Warning (BayStream software only)
Message: Primary and secondary clocks unoperational - Switching to Internal Clock Source.
Meaning: The primary and secondary sources of timing signals (specified by the Primary Clock
Source and Secondary Clock Source global parameters) have been withdrawn or have
failed. MCT1 will attempt to generate timing signals internally.
Action: Check cabling of the primary and secondary clock sources.
Entity Code/Event Code 63/34
Decimal Identifier 16793378
Severity: Warning (BayStream software only)
Message: Connector COM <connector_no.> Loop timing source OK.
Meaning: MCT1 is receiving valid loop timing signals from Port 0 or Port 1.
Action: None required.