Event Messages for Routers
7-126
303550-A Rev 00
Entity Code/Event Code 98/60
Decimal Identifier 16802364
Severity: Trace
Message: Sent NEW PRI pdu.
Meaning: The router has sent a New Primary PDU. The New Primary PDU indicates that a role
change has occurred, and a new router has assumed the primary role.
Entity Code/Event Code 98/61
Decimal Identifier 16802365
Severity: Trace
Message: REF_NUM_CHGD - gid: <group_ID>, mid: <member_ID>, cct: <circuit_no.>
ref_num: <reference_no.>, pri: <value>, bsec: <value>, gif: <value>,
gres: <value>
Meaning: The router redundancy database has a new reference number.
Entity Code/Event Code 98/62
Decimal Identifier 16802366
Severity: Trace
Message: SOS_TYPE_PDU - gid: <group_ID>, mid: <member_ID>, cct: <circuit_no.>
ref_num: <reference_no.>, pri: <value>, bsec: <value>, gif: <value>,
gres: <value>
Meaning: The router redundancy data base has been updated by a new SOS PDU.
Entity Code/Event Code 98/63
Decimal Identifier 16802367
Severity: Trace
Message: NEW MEMBER - gid: <group_ID>, mid: <member_ID>, cct: <circuit_no.>
ref_num: <reference_no.>, pri: <value>, bsec: <value>, gif: <value>,
gres: <value>
Meaning: The specified new member has joined this router redundancy group.
Entity Code/Event Code 98/64
Decimal Identifier 16802368
Severity: Trace
Message: MEMBER TIMEOUT - gid: <group_ID>, mid: <member_ID>, cct: <circuit_no.>
Meaning: The specified redundant group member has timed out.
Comments to this Manuals