Event Messages for Routers
9-90
303550-A Rev 00
Entity Code/Event Code 31/41
Decimal Identifier 16785193
Severity: Info
Message: Network <network_address> mapped to cct <circuit_no.>
Meaning: The interface for the network indicated is monitoring the status of the associated circuit.
Entity Code/Event Code 31/46
Decimal Identifier 16785198
Severity: Info
Message: Traffic Filter - drop: Rule <filter_rule_no.>, circuit <circuit_no.> Network
<network_address> Host <host_address>
Meaning: A packet matching filter rule <filter_rule_no.> was received on <circuit_no.>. The
packet was dropped as specified by the filter.
Entity Code/Event Code 31/47
Decimal Identifier 16785199
Severity: Info
Message: Traffic Filter: Rule <filter_rule_no.>, circuit <circuit_no.>
Meaning: A packet matching filter rule <filter_rule_no.> was received on <circuit_no.>. The
packet was dropped as specified by the filter.
Entity Code/Event Code 31/48
Decimal Identifier 16785200
Severity: Info
Message: RTM out of BUFFERS
Meaning: The Routing Table Manager process is out of buffers. This condition hinders propagation
of information to other slots.
Trace Events
Entity Code/Event Code 31/7
Decimal Identifier 16785159
Severity: Trace
Message: Network <network_address> added to Table of Networks
Meaning: The network indicated was added to the table of networks.