Avaya Event Messages for Routers User Manual Page 331

  • Download
  • Add to my manuals
  • Print
  • Page
    / 928
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 330
Event Messages (FDDI through FR_SVC_API)
303550-A Rev 00
4-3
Entity Code/Event Code 8/69
Decimal Identifier 16779333
Severity: Fault
Message: Node <FDDI_connector_no.> illegal TMaxLowerBound value
<TMaxLowerBound_value> requested.
Meaning: You entered an invalid value for wfFddiTMaxLowerBound (T_Max Lower Bound). The
following relationship must be true:
wfFddiMaxLowerBound > or = wfFddiMacTReq [Requested TTRT] and > or = 10 ms.
and < 1336.9344.
Action: Check the value entered for wfFddiTMaxLowerBound.
Entity Code/Event Code 8/70
Decimal Identifier 16779334
Severity: Fault
Message: Node <FDDI_connector_no.> illegal TraceMaxExpiration value
<TraceMaxExpiration_value> requested, must be > <value> ms.
Meaning: You entered an invalid value for wfFddiSmtTraceMaxExpiration (Trace Max Expiration).
The value entered must be greater than 6.1 ms.
Action: Check the value entered for wfFddiSmtTraceMaxExpiration.
Entity Code/Event Code 8/71
Decimal Identifier 16779335
Severity: Fault
Message: Node <FDDI_connector_no.>, phy <A | B> - illegal LerCutOff value
<LerCutOff_value> requested (range: 4 - 15).
Meaning: You entered an invalid value for wfFddiPortLerCutOff (LER Cutoff). The value entered
must be between 4 and 15, inclusive.
Action: Check the value entered for wfFddiPortLerCutOff.