Avaya IP500 V2 Operations Instructions Page 243

  • Download
  • Add to my manuals
  • Print
  • Page
    / 442
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 242
Installing IP500/IP500 V2 Page 243
15-601042 Issue 28g (11 October 2013)IP Office 9.0
System Components: IP500 External Expansion Modules
Module Rear
Ports
Description
ANALOG
RJ45 socket. Used for connection to analog trunks. Ports can be configured as either loop-start or
ground-start trunks through the IP Office configuration.
In the event of power failure, Analog ports 1 and 2 are directly connected to analog extension ports PF1
and PF2 respectively. If used the connected phones must be clearly labeled as power failure devices.
This is only supported for loop-start analog trunks.
DC I/P
DC power input port. Used for connection of the power lead from an Avaya 40W external power supply
unit supplied with the expansion module. A locale specific IEC60320 C7 power cord for the external
PSU is required but is not supplied with the module.
DTE
25-Way D-Type socket. For Avaya use only.
EXPANSION
RJ45 Socket. Used for direct connection to an Expansion port on an IP Office control unit using the
Expansion Interconnect cable supplied with the module.
PF
RJ45 socket. Power failure analog extension ports. See Analog section above.
Ground point. Used for connection of a functional earth if required. On older modules where this
screw is not present, the top-center cover screw should be used instead.
· IMPORTANT
In all IP Office installations, any module being used for analog trunk connections must be connected
to a functional earth .
· WARNING
Within areas of high lightning risk, any module using analog trunk connections must be connected to
a protective ground and to surge protection equipment .
Part Codes and Related Equipment
All expansion modules are supplied with a base software level and should be upgraded to match the core software of the
control unit in the IP Office system. Expansion modules include an external power supply unit (PSU) and an appropriate
interconnect cable. They do not include a locale specific power cord for the external PSU or any phone extension cables.
Item
Variant
Country
SAP Code
IPO IP500 EXP MOD ANLG TRNK 16
America
America
700449473
IPO IP500 EXP MOD ANLG TRNK 16 TAA
" Trade Agreements Act
compliant variant.
America
700501511
IEC60320 C7 Power Cord
NEMA1-15
America
700213390
Mounting Kit
IPO IP500 RACK MNTG
KIT V3
All
700503160
391
394
39
396
398
44
44
44 45
422
205
Page view 242
1 2 ... 238 239 240 241 242 243 244 245 246 247 248 ... 441 442

Comments to this Manuals

No comments