Installing IP500/IP500 V2 Page 244
15-601042 Issue 28g (11 October 2013)IP Office 9.0
10.5.2 BRI So8
The So8 module can be used to add ETSI BRI S0-interface ports to the IP Office system. These ports can then be used
for the connection of ISDN devices.
IP500 and IP500 V2. The control unit must be running in IP Office standard mode.
Supported in all IP Office locales .
IP Office core software level 1.0 minimum. Bin file = nas0-16.bin.
Power supply unit (see below) and Expansion Interconnect cable.
The unit is supplied with an earthed 3-Pin, 60W external power supply unit. The PSU has an
integral power cord for connection to the unit's DC I/P socket. A locale specific IEC60320 C13
power cord for the external PSU is required but is not supplied with the unit.
The module is designed as a free-standing module that can be stacked on or under other IP Office
modules. The module can be wall or rack mounted using the IPO IP500 RACK MNTG KIT V3 .
Width: 445mm/17.5". Depth: 245mm/9.7". Height: 71mm/2.8"/2U.
Unboxed: 2.8Kg/6.3lbs. Boxed: 4.1Kg/9.2lbs.
Module Front
· Green On = Connected.
· Green Flashing = Activity.
The center LED on all external expansion modules is used to indicate the overall state of the module as
follows:
· Red flashing = Module starting up/Loading firmware.
· Red on = Error.
· Green on = Module okay.
51
39
279