Page view 274
Installing IP500/IP500 V2 Page 275
15-601042 Issue 28g (11 October 2013)IP Office 9.0
System Components: IP400 Expansion Modules
10.9.5 Phone
The IP400 Phone module (also known as the Phone V1 module) is used to add additional POT ports to an IP Office
system. POT ports are used for analog phones.
The Phone module is available in 8, 16 and 30 port variants, referred to as the Phone 8, Phone 16 and Phone 30
respectively. The IP400 Phone Module has been superseded by the Phone Module V2 .
· With IP Office 3.1 and higher, the message waiting indication (MWI) on each POT port can be configured for None, On,
51V Stepped, 81V, Line Reversal A or Line Reversal B. On uses the default determined by the system locale. POT ports
on a Phone V2 module can additionally be configured for 101V operation.
Feature
Details
Supported on
All IP Office control units except Small Office Edition.
Locales
Supported in all IP Office locales .
Software Level
IP Office core software level 1.0 minimum. Bin file = napots16.bin (earlier units, not supported on
IP500) or avpots16.bin (later units).
Included
Power supply unit (see below) and Expansion Interconnect cable.
Power Supply
The module is supplied with a 2-pin, 40W external power supply unit. The PSU has an integral
power cord for connection to the module's DC I/P socket. A locale specific IEC60320 C7 power
cord for the external PSU is required but is not supplied with the module.
Mounting
The module is designed as a free-standing module that can be stacked on or under other IP Office
modules. The module can be rack mounted in a 19" rack system using the optional IP400 Rack
Mounting Kit.
Dimensions
Width: 445mm/17.5". Depth: 245mm/9.7". Height: 71mm/2.8"/2U.
Weight
Unboxed: 3.1Kg/6.94lbs. Boxed: 4.4Kg/9.7lbs. (Based on Phone 30 V2).